GW-LCR-8105G

SKU
GW-LCR-8105G
Weight
5,00 KG


Brochure/Video


Our price:
6.708,00 (6.154,13)

Model GW Instek GW-LCR-8105G
Precision LCR Meter - 20Hz~5MHz - ±0.1% - 6 digits resolution

  • Wide Test Frequency 20Hz ~ 5MHz
  • 0.1% Basic Accuracy & 6 Digits Measurement Resolution
  • Large LCD Display with Intuitive Interface
  • Full Measuring Functions with DUT V/I Monitor
  • PASS/FAIL Function (abs, % or delta) with Judgment Alarm
  • Average 1 ~ 256 Times
  • DC Resistance Measurement
  • Multiple Step Mode
  • Graph Mode
  • Standard RS-232C / GPIB Interface
  • Optional DC Bias box

The GW Instek GW-LCR-8000G Series LCR meters offer test frequencies up to 10MHz, and provide accuracy, versatility and high resolution for a wide range of component measurements, even including DC resistance measurement and Voltage/Current monitoring. The Multi-Step function allows on-screen programming of customised measurement sequences with Pass/Fail indication. Each program includes 30 test steps and each test step can be set with selected parameters and test limits. Under Multi-Step operation, tedious work routines can be performed step by step automatically just at the press of a button. With Graph Mode, GW-LCR-8105G displays the component impedance response, either over a wide range of test frequency sweep or over a wide range of test voltage sweep in a graph chart. This gives an analysis result of either impedance vs. frequency or impedance vs. applied voltage, all at a glance. GPIB and RS-232C interfaces are standard for instrument control and test result display on the PC. The rich features of the GW-LCR-8105G enables your measurement tasks at a very competitive price.

The GW Instek GW-LCR-8000G Series is designed to perform precision impedance measurements over a wide frequency range of 20Hz~10MHz for the GW-LCR-8110G, 20Hz~5MHz for the GW-LCR-8105G and 20Hz~1MHz for the GW-LCR-8101G.The instrument is capable of measuring 11 different parameters with 0.1% basic accuracy, which meets the precision measurement requirements of components and modules used in the RF circuits. The large LCD display with single-layer operation menu of GW-LCR-8105G provides users with ultimate convenience to plug and play without much learning time.

In the GW Instek GW-LCR-8105G Pass/Fail test, the primary parameter measurement result is compared with user-defined limits and the pass or fail result is then displayed. Three methods, including absolute limit, percentage and delta limit, are available for Hi (high) and Lo (low) limit setting based on the nominal test value. The Pass/Fail test checks whether the parameter measurement result sits within the limits, then display "PASS" for within the limits, or "LO" for lower than the low limit, or "HI" for higher than the high limit. A scale and bar for displaying measurement result is shown at the center of the screen to give a graphical identification, which greatly reduces operator's inspection time. This scale and bar also facilitate the adjustment of the variable components. Either Pass or Fail result can be set with a buzzer alarm, which makes component or material sorting easy with sound identification.

The GW Instek GW-LCR-8105G Multi-Step mode is capable of running a series of measurements of a component at a number of user-defined steps in sequence automatically. Total of 64 programs can be saved into the non-volatile memory, and each program contains up to 30 test steps. The parameter and Hi/Lo limits can be set respectively for each test step. After a program has been properly edited, the instrument can run through all the measurement steps either at a press of the button under the Manual Trigger selection, or automatically run the program by detecting the connection of a DUT under the Auto Trigger selection. When all the test steps are completed, the screen shows the measurement reading of the parameter being selected for each step with Pass, HI, or LO measurement result.

The graph function shows the component characteristics in a visual manner. Either voltage sweep or frequency sweep can be selected for horizontal scale. Just select the parameter, and set the start/stop voltage or the start/stop frequency of the sweep, The GW Instek GW-LCR-8105G will run through the sequence of measurements and show the results on a graph. This graphical parameter measurement performs the characteristic verification of components and materials over the response to the changes in AC test frequency or AC test voltage without the need of complex programming of an external controller. When the graph moves out of the vertical range, the GW-LCR-8105G can automatically adjust the scale to get full test information. On the graph, the marker operation is available for detailed observation.

Scope of Delivery:

  • GW Instek GW-LCR-8105G: Precision LCR Meter
  • Power Cord
  • User manual
  • LCR-12: Test Lead

Optional Accessories (not included):

  • Test Fixtures
    • LCR-05, for Axial & Radial Lead Components
    • LCR-06A, Kelvin Clip Test Lead
    • LCR-07, Two-Wire with Alligator Clips
    • LCR-08, Tweezers for SMD/Chip Components
    • LCR-09: for SMD/Chip components
    • LCR-12: Test Lead with Kelvin clip (4 wire type)
    • LCR-13: Test Fixture for SMD/Chip components
  • GTL-232, RS-232C Cable, 9-pin Female to 9-pin, Approx. 2m
  • GRA-404: Rack Adapter Panel (19", 4U)
  • GTC-001: Instrument Cart
  • GTC-002: Instrument Cart


: *
: *
: *
Type the characters you see in the picture:


*
The code is case-sensitive and must be entered exactly as above.
GW Instek GW-LCR-8105G Precision LCR Meter
GW Instek GW-LCR-8105G Precision LCR Meter
GW Instek GW-LCR-8105G Precision LCR Meter
AD-USB-1901
 
The cookie settings on this website are adjusted to allow all cookies so that you have the very best experience. If you continue without changing your cookie settings, we'll assume that you are happy to receive all cookies on our website. However, if you would like to, you can change your settings at any time using the Change cookie settings link in the Special menu.