Model Marvin Test Solutions: MV-GX1034
Standard Reference Module

  • 3U, single slot, precision standards module for PXI systems
  • Voltage, frequency, and resistance standards
  • On-board EEPROM ensures standards traceability and accuracy
  • Built in current source and DC measurement resources for system self-test support
  • Built-in self test
  • Compatible with PXI Express hybrid slots

The Marvin Test MV-GX1034 offers PXI system designers the capability to develop a system re-certification strategy that employs only internal system resources. By incorporating the MV-GX1034 as part of a system configuration, it is possible to develop a system accuracy verification strategy that can recertify a system’s source and measure baseband instrumentation – resulting in simplified support / maintenance logistics and improved system availability.

The Marvin Test MV-GX1034’s standards exhibit excellent long term stability with absolute accuracy achieved by employing an on-board EEROM, which contains NIST traceable calibration values for source and resistor standards. The module also includes source and measure resources which can be used to support system self-test functions including continuity verification and verification of instrument functionality.

Features

The Marvin Test MV-GX1034 provides a DC voltage source reference, an AC voltage source reference, 8 low drift resistor references, and a precision 10 MHz frequency reference. The DC and AC sources supply up to ±9 V and include a 3 decade resistive divider network for attenuation of the output level. The resistor references include four-wire 1, 10 and 100 Ω resistors and two-wire 1 K, 10 K, 100 K, 1 M and 10 MΩ resistor values. The 10 MHz frequency reference employs a high stability, oven controlled crystal oscillator which can also provide lower frequencies via a 24-bit divider. Both the 10 MHz output and the divider output can drive 50 Ω loads. In addition, when the module is installed in slot 2 of a PXI chassis, it can be the PXI 10 MHz backplane clock source.

Additional features include a 0 - 20 mA current source; a 16-bit A to D for measuring voltages up to ±10 V, and on-board monitoring of the card’s ambient operating temperature. The card also includes a signal multiplexer which provides the ability to connect two and four wire resources to the card’s output connector. All voltage resources, resistor standards, clock divider outputs, and A to D inputs are isolated and floating from the PXI bus, ensuring a low noise environment and minimizing the possibility of ground loops which can affect overall accuracy and performance.

Scope of Delivery:

  • Marvin Test Solutions MV-GX1034: Standard Reference Module
  • Manual
  • Certificate of Calibration

Marvin Test Solutions


: *
: *
: *
Type the characters you see in the picture:


*
The code is case-sensitive and must be entered exactly as above.
Marvin Test MV-GX1034 Standard Reference Module
AP-LS500
€ 3.291,00
 
The cookie settings on this website are adjusted to allow all cookies so that you have the very best experience. If you continue without changing your cookie settings, we'll assume that you are happy to receive all cookies on our website. However, if you would like to, you can change your settings at any time using the Change cookie settings link in the Special menu.